West 6010 Manual
- Recovery of claims. This Manual supersedes DoD 6010.15-M, “Military Treatment Facility Uniform Business Office (UBO) Manual,” April 1997 (hereby canceled) (Reference (b)) and is mandatory for use by all DoD Components and MTFs. This Manual applies to the Office of the Secretary of Defense, all Military Departments, the.
- Apr 01, 2015 TRICARE Reimbursement Manual 6010.61-M, April 2015; TRICARE Systems Manual 7950.3-M, April 2015; TRICARE Program Manuals - 2008 Edition (T-3). These manuals are applicable to the East and West Regional Managed Care Support Contracts awarded on or after. Upon direction of the Contracting Officer, all or portions of these manuals.
- West 6010 & 8010 Panel Indicator Jumperless Configuration Auto Detected Hardware Up to 4 Alarm Outputs Modbus & ASCII Comms Min/max Value Hold Tare (auto-zero) Function Multi-point Scaling PC configuration The P6010 and P8010 have multi-point scaling, tare function and improved flexibility. They have a universal input.
- West 6010 Manual Diagram
- West 6010 Manual Online
- 6010 Manual Us Navy
- Navsea 6010 Manual
- Marantz 6010 Manual
- West 6010 Manual Portugues
- West 6010 Manual
West P6010 and P8010 Panel Indicator. The P6010 and P8010 have multi-point scaling, tare function and improved flexibility. They have a universal input and are available with a red or green display. Plug-in modules allow up to four alarm relays (latching or non- latching), PV retransmission or transmitter PSU.
1
/
4
-DIN,
1
/
8
-DIN &
1
/
16
- DIN Controllers & Indicators - Product Manual
59305, Issue 7
– March 2014
Powering Up
Page 37
6 Messages and Error Indications
The following displays are shown when an error occurs or a hardware change is detected.
Table 4. Error/Faults conditions
Error/Faults Conditions
Upper display
Lower Display
(where fitted)
1
/
8
DIN Indicator
Units Display
West 6010 Manual Diagram
Configuration & Setup is required.
Seen at first turn on or if hardware
configuration changed.
Press to enter Configuration
Mode,
next press or to enter the
unlock code number,
then press to proceed.
Configuration must be completed
before return to operator mode is
allowed
1
( for 1
second, then
on
Indicators)
Input more than 5% over-range
2
*
Normal Display
Normal Display
Input more than 5% under-range
3
West 6010 Manual Online
*
Normal Display
Normal Display
Sensor Break. Break detected in
the input sensor or wiring
*
Normal Display
Normal Display
Auxiliary input over-range
Normal Display
*
n/a
Auxiliary input under-range
Normal Display
*
n/a
Auxiliary Break. Break detected in
the auxiliary input
Normal Display
*
n/a
Option 1 module fault.
**
Option 2 module fault.
**
Option 3 module fault.
**
Option A module fault.
**
6010 Manual Us Navy
Option B module fault.
* Note
Input sensor and Auxiliary over/under-range or break indications will be seen wherever
these values would normally be displayed.
** Note
Option module number follows error legend on
1
/
16
DIN Indicators (e.g. )
1
Navsea 6010 Manual
This feature does not guarantee correct configuration. It only helps to ensure that the unit will be configured
before use. Use of set-up mode is not enforced but may be essential for the users application.
2
If the PV display exceeds
before 5% over-range is reached, an over-range indication is given.
3
Indicators will allow up to 10% under-range on non-zero based Linear ranges. If the PV display is less than
before the % under-range is reached, an under-range indication is given.